Installed in a PVC DWV piping system to allow for a 90 degree change of direction from vertical to horizontal, horizontal to horizontal and horizontal to vertical.
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • For use in both the drainage and venting sections of the plumbing installation • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in an PVC DWV piping system to allow for a long turn 90 degree change of direction from vertical to horizontal, horizontal to horizontal and horizontal to vertical.
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • For use in both the drainage and venting sections of the plumbing installation • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a PVC DWV piping system to allow for a long turn 90 degree change of direction from vertical to horizontal, horizontal to horizontal and horizontal to vertical. A conversion fitting that changes the piping from a Hub to a Spigot termination.
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • For use in both the drainage and venting sections of the plumbing installation • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed at the mounting location of an PVC DWV Closet Flange to transition from the Closet Flange Installed inside the 4" Hub of the reducer bend to the 3" Hub that connects to the PVC DWV drainage system.
Features
• Injection molded in non-toxic durable white polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Normally used in the drainage portion of the DWV system only • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a PVC DWV piping system to provide an extra long 1/6 or 60 Degree change in direction from vertical to horizontal or horizontal to horizontal.
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • For use in both the drainage and venting sections of the plumbing installation • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a PVC DWV piping system to provide a tight or short 45 degree change in direction where space is a concern. From vertical to horizontal, horizontal to horizontal and horizontal to vertical. Also known as a 1/8 bend or elbow.
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • For use in both the drainage and venting sections of the plumbing installation • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a PVC DWV piping system to allow for a long turn 45 degree change of direction from vertical to horizontal, horizontal to horizontal and horizontal to vertical. A conversion fitting that changes the piping from a Hub to a Spigot termination or a spigot to a Hub termination.
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • For use in both the drainage and venting sections of the plumbing installation • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a PVC DWV piping system to provide 1/16 or 22-1/2 Degree change in direction from vertical to horizontal or horizontal to horizontal..
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • For use in both the drainage and venting sections of the plumbing installation • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source