Installed in a vertical PVC DWV piping system to allow for a smooth transition from a horizontal branch line to a vertical pipe drainage line.
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints • For use in both the drainage and venting sections of the plumbing installation
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a vertical PVC white DWV piping system to allow for a smooth transition from a horizontal branch line and a branch line from the left into the vertical drainage line.
Features
• Injection molded in non-toxic durable white polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints • For use in both the drainage and venting sections of the plumbing installation
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a vertical PVC white DWV piping system to allow for a smooth transition from a horizontal branch line and a branch line from the left into the vertical drainage line.
Features
• Injection molded in non-toxic durable white polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints • For use in both the drainage and venting sections of the plumbing installation
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a PVC white DWV vertical drainage system Hub to allow for a smooth horizontal transition from a horizontal branch line into the drainage pipe.
Features
• Injection molded body in non-toxic durable white polyvinyl chloride (PVC) • For use in both the drainage and venting sections of the plumbing installation • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Flame retardant, will not support combustion in the presence of an ignition source • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a PVC DWV piping system within the venting portion only. The tee provides an entrance into a Vertical piping Stack from a Horizontal Side Branch
Features
• Injection molded in non-toxic durable polyvinyl chloride (PVC). • Flame retardant, will not support combustion in the presence of an ignition source • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Use approved PVC primer and solvent cement to make PVC joints
• Flame retardant, will not support combustion in the presence of an ignition source • Flame retardant, will not support combustion in the presence of an ignition source • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a vertical PVC white DWV piping system to allow for a smooth transition from two horizontal branch lines.
Features
• Injection molded in non-toxic durable white polyvinyl chloride (PVC). • Service temperature rated at (140F) +60C • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • For use in both the drainage and venting sections of the plumbing installation • Use approved PVC primer and solvent cement to make PVC Joints
• Flame retardant, will not support combustion in the presence of an ignition source • Normally used in the drainage portion of the DWV system only • Flame retardant, will not support combustion in the presence of an ignition source
Installed in a 3" PVC white DWV vertical pipe to accept two (2) 1-1/2" inlets from two (2) opposite directions or side by side. Could be two sinks back to back in different rooms or two sinks side by side in the same room. Can be used to drain or vent.
Features
• Injection molded body in non-toxic durable white polyvinyl chloride (PVC) • Service temperature rated at (140F) +60C • For use in both the drainage and venting sections of the plumbing installation • High chemical resistance to acids, alkalis, alcohols, halogens, and other corrosive media • Compact design, eliminates the need to stack two (2) 3" X 1-1/2" tees on top of each other, avoiding complicated installations
• Use approved PVC primer and solvent cement to make PVC Joints • Flame retardant, will not support combustion in the presence of an ignition source • Flame retardant, will not support combustion in the presence of an ignition source